Weather Louvres WL |
|
TYPE WLL | Weather Louvre manufactured of extruded Type 50S anodising grade aluminium. The fixed horizontal blades are held in place by screws. Blades are spaced 35mm apart. | |||
Standard Spacing | Top blade fits flush with frame. Lip of Bottom Blade overlap frame. | |||
Accessories | WM | = Wire Mesh | ||
OBD | = Opposed Blade Damper NOTE: Adjustment from face of Louvre is not advisable. | |||
PC | = Punched Counter Sunk Holes | |||
Dimensions | ON | = Normal Duct size | ||
Notes | (1) | Alternative Meshes available on request | ||
(2) |
For Weather Louvres smaller than 450 x 300 we recommend the use of Type RA with RASB Blade with19mm spacing. | |||
Type WLL: | Weather Louvre | |||
Vermin Protection: | = Plastic Bird mesh - Standard | |||
= Galvanised wire mesh | ||||
Frame Options | 50mm | Standard | ||
30mm | ||||
Finishing Options | NA | = Natural Anodised | ||
EPC | = Epoxy Powder Coating | |||
Ordering Procedure: Example | |||||||
REF | QTY | SIZE (LxH) | TYPE | ACCESS | FRAME | FINISH | SPECIAL INSTRUCTIONS |
1 | 12 | 1000 x 850 | WLL | - | 50 | NA | ON - FS |
Note: |
(1) Dimensions given are for opening size into which grille will fit |
(2) If code "OS" is entered under SPECIAL INSTRUCTIONS, then dimensions given are over flange |
Opposed Blade Damper - OBD |
|
Determine the sound level which results from the combined effects of several sound sources is not as difficult as it is confusing. |
|
|
|
|
|
If the difference between NC levels of two units is 10db or more, the sound generated by the quieter unit will not affect the space NC. |
|
TYPE OBD |
Opposed Blade Damper manufactured from extruded aluminium Blades. Blades are held in place by spring wire and star lock push on fix. The OBD blades are linked and lever or slot operated. OBD suits all standard grilles and diffusers. |
|||
Blade Options: | Standard as per sketch | |||
Finish Options: | PR | = Primed Black (Optional) | ||
MF | = Mill finish (Standard) | |||
Blade Spacings | 25mm | Standard | ||
Ordering Procedure: Example | |||||||
REF | QTY | SIZE (LxH) | TYPE | ACCESS | FRAME | FINISH | SPECIAL INSTRUCTIONS |
2 | 10 | 381 x 381 | OBD | - | STD | MF | TO FIT CD |
Note: |
(1) Dimensions given are for - To fit ON of mother grille |
(2) If OBD to fit grille, indicate type of grille, outside neck size. |
Weather Louvres - WLL |
|
TYPE WL | Weather Louvre manufactured of extruded Type 50S are held in place by screws. Blades are spaced 50mm apart. | |||
Standard Spacing | Top blade fits flush with frame. Lip of Bottom Blade overlap frame. | |||
Accessories | WM | = Wire Mesh | ||
OBD | = Opposed Blade Damper NOTE: Adjustment from face of Louvre is not advisable. | |||
PC | = Punched Counter Sunk Holes | |||
Dimensions | ON | = Normal Duct size | ||
Notes | (1) | Alternative Meshes available on request | ||
(2) |
For Weather Louvres smaller than 450 x 300 we recommend the use of Type RA with RARB Blade with19mm spacing. | |||
Type WL: | Weather Louvre | |||
Vermin Protection: | = Plastic Bird mesh - Standard | |||
= Galvanised wire mesh | ||||
Finishing Options | NA | = Natural Anodised | ||
EPC | = Epoxy Powder Coating | |||
Ordering Procedure: Example | |||||||
REF | QTY | SIZE (LxH) | TYPE | ACCESS | FRAME | FINISH | SPECIAL INSTRUCTIONS |
1 | 12 | 1000 x 850 | WL | - | 50 | F.S. |
Note: |
(1) Dimensions given are for ON size |
(2) If code "OS" is entered under SPECIAL INSTRUCTIONS, then dimensions given are over flange |
Custom made products |
|
|
|
© 2024 Air Movement Equipment